Transferring heat
Thermal oil systems are used for heat transfer in industrial applications.
A thermal oil system transfers heat to industrial processes using thermal oil as the heat transfer medium. Depending on the grade, the oil stays liquid up to approx. 315 °C. Combined with an ORC module, the system also generates electricity and district heat. Kablitz supplies thermal oil heaters from approx. 5 MWth, as membrane wall boilers or single-pass boilers.

A steam boiler supplies steam for industrial processes or a steam turbine. A thermal oil system transfers heat through liquid heat transfer oil and can be combined with an ORC module. The form of energy required by the process determines the choice. Fuel, operating conditions and scope of supply are coordinated for the individual project.
| Selection criterion | Steam boiler | Thermal oil system |
|---|---|---|
| Heat transfer medium | Steam | Liquid thermal oil |
| Process heat | Steam for heating industrial processes | Heat transfer through a thermal oil circuit |
| Power generation | Combined with a steam turbine | Combined with an ORC module |
| Initial design data | Required steam mass flow, pressure and temperature | Required heat output and temperatures in the thermal oil circuit |
The original ORC process diagram complements the documentation on combining thermal oil systems with electricity and district heating generation. It does not replace plant-specific engineering.
Original image · product detail
Material, media and structure determine the specific design.
Thermal oil systems are used for heat transfer in industrial applications.
Thermal oil plants can be combined with ORC modules that generate electricity and district heating.
The thermal oil remains liquid within the permissible temperature range. Depending on the type of oil, up to approx. 315 °C is possible.
The design depends on the specific plant.
| Product | Design | Application | Details |
|---|---|---|---|
| Membrane wall boiler | Membrane wall boiler | Membrane wall boiler for a plant-specific design. | View details |
| Single-pass boiler | Single-pass boiler | Single-pass boiler for a plant-specific design. | View details |
| Three-pass boiler | Three-pass boiler | Three-pass boiler for a plant-specific design. | View details |

Membrane wall boiler for a plant-specific design.
Membrane wall boiler for a plant-specific design.

Single-pass boiler for a plant-specific design.
Single-pass boiler for a plant-specific design.

Three-pass boiler for a plant-specific design.
Three-pass boiler; design and limits are defined for each plant.

Loading plays the video from YouTube (Google) in privacy-enhanced mode and sends information including your IP address and browser data to Google. Privacy
Biomass CHP plant
Ask Kablitz for the technical documents relevant to your product and application.
Last updated:
Request documents by emailDiscuss media, temperatures and installation conditions with Kablitz.
Get in touchA thermal oil system takes up the heat from the furnace and passes it to the process through a liquid heat transfer oil. Depending on the oil grade, the oil stays liquid up to roughly 315 °C; whether that is enough for your process depends on the chosen oil and the plant. Kablitz supplies thermal oil heaters from roughly 5 MWth as membrane wall, single-pass or three-pass boilers. State the required temperature and output in your inquiry. If electricity is needed, the system can be combined with an ORC module.
Steam boilers, if process steam is neededFor an initial discussion, provide the following information where available:
Yes. Technical checklist fields are optional: provide the data you already know and leave outstanding points for further discussion.
Start a project inquiry